Engineering | Knowledge | Technology

Plastering Works



























GENERAL PROVISIONS
These instructions include the following types of work:
- Exterior plasterwork, two-layer and multilayer, for various structures
- Interior plasterwork with water-repellent additives
- Special plasterwork:
• soundproof plasterwork;
• anti-radiation plasterwork;
• heat-insulating plasterwork;
• decorative plasterwork.
Norms for the following types of work must be taken into account:
- Work with concrete - cast-in-place concrete;
- Work with concrete - concrete for precast items;
- Masonry/brickwork;
- Floor-base work.

DOCUMENTATION TO BE SUBMITTED
The following documentation shall be submitted to the Engineer:
- A catalogue of products indicating how they are to be used
- Instructions for using products
- Manufacturers' certificates confirming that products comply with
specifications.

QUALITY ASSURANCE
The quality of finishing work shall comply with the agreed international standards.
Mortar used shall be checked in accordance with the agreed international standards.

MATERIALS
Plasterwork shall be done in accordance with the agreed international standards. The
standards given in those norms are in force as appropriate.

EXECUTION OF WORK
Allowance must be made for correct installation and inspection of all openings, built-in
items, interior sanitary and electrical networks, and other types of work.
All surfaces must be checked for cleanliness.
Smooth bases shall be fully scratched.
Highly-absorbent bases shall be dampened before starting work.
Plasterwork bases (netting) shall be firmly fixed so that they does not sag or bend.
Fastenings shall be strong and no damage from corrosion shall appear.
Plasterwork netting shall overlap at joins by a minimum of 5 cm. Overlaid accessories
protecting corners and edges shall be strictly vertical or horizontal as appropriate for their
locations.
Preparation of bases for plasterwork shall be appropriate for the particular features of the
plasterwork to be done.
Netting must be installed at places where plasterwork borders on door frames or built-in
wooden components.
Steel structures, steel fasteners etc. which are to be incorporated shall be hot-galvanized.
Surfaces of dissimilar metals which come into contact shall be protected against contact
electrolytic corrosion.